NETZSCH Lohnmahltechnik's headquarters in Bobingen features a modern building with large windows and a clear blue sky backdrop, emphasizing innovation in material processing.

Toll Grinding

Bobingen

Bobingen is the location of the NETZSCH Lohnmahltechnik GmbH headquarters. Here we offer micronization of dry materials into the nanometer range.
Jet mills, primary crushers, crushers, classifiers and screening machines are available in Bobingen for processing your products. There is also a large testing laboratory / pilot plant for the development of your products.

MachinesFineness / Characteristics
Fluidized Bed Millsrange from 5 - 100 µm
Dynamic Classifiersrange from 5 - 100 µm (d97)
Impact Millsrange from 50 - 500 µm / Long gap mills
Hammer Millsrange from 500 µm - serveral mm
Classifier MillsCSM from 10 - 150 µm (d97) / Rotor impact with integrated dynamic classifier
Packaging Machinesfor Sacks / Big Bags / Tons / Inliner / Drums
Laboratory EquipementAir jet screens / CILAS (water, alcohol) / Malvern 3000 wet and dry / Microscop / Humidity measurement

Product Examples

  • Activated carbon
  • Graphite
  • Glazes/Frits
  • Oxides
  • Hydroxides
  • Carbonates
  • Synthetic materials
  • Recycled products
  • Fertilizers, agricultural products
  • Cellulose
  • Aggregates

ISO Certifications

For NETZSCH Lohnmahltechnik, ISO certifications such as ISO 9001, 14001, and 50001 offer significant advantages. They highlight our commitment to the highest quality standards, environmental responsibility, and energy efficiency. These certifications not only demonstrate our expertise but also strengthen the trust our customers and partners have in our services.

ISO 9001 certified badge highlighting quality assurance for NETZSCH’s grinding and dispersing services.

ISO 9001: Quality Management

We got our new Certificate dated July 22, 2024. The audit was passed without major nor minor deviation. 

Especially newest legal request regarding global heating was shown by means of context analysis properly. Managementsystem „viflow“ was replaced by „Q.wiki“ and already presented. Motivated by customer wishes and requirements from safety at work, there have been prepared new instruction manual, risk analysis and process instructions.

ISO 14001 certification badge ensuring environmental management excellence in NETZSCH Lohnmahltechnik operations.

ISO 14001: Environmental Management

First repeated audit was held November 2023. The audit result was without major and minor deviation.

All production plants at NETZSCH Lohnmahltechnik are authorized by means of BImSchG and are regularly monitored during operation. Actual measurements of outgoing air showed a residual dust content of 0.002 mg/m³ for example material with a limited value of 0.5 mg/m³, which shows a value far beyond the limited residual dust content. Another example for a regular material with a limit at 20 mg/m³ the measured value showed 0.4 mg/m³.

Waste separation was improved further, that a separation at the best possible rate according to KrWG could achieved.

Every new material to be toll processed is professionally classified by means of a self-developed risk analysis tool, to ensure that toll processing is safely for our operators.

ISO 50001 certification emblem highlighting NETZSCH's commitment to energy management and sustainability standards.

ISO 50001: Energy Management

Repeated audit took place at Bobingen on June 26, 2024, and in Hanau on July 16, 2024. 

ISO 50001 requires a continuously improvement in energy saving. Therefore, an intensive data analysis of existing measurements for consumption of compressed air, electricity and produced material amount has been made. Using mathematic linear regression method linear equation could be found. That equation considers variables such as maximum particle size of fine product, grinding type, grinding pressure, ambient conditions and material hardness.

The result of analytical calculated value confirms the real invoiced electricity consumption by 96 %, that is independent whether at Bobingen or Hanau site.

Tailored Toll Processing

Precision and quality for your products.

Contact us
AI Overview
An error occurred. Please try again.