Application seminar

Analysis and Optimization of Wet Grinding Processes

from Laboratory to Production Scale

THEORY | Analysis and Optimization of Wet Grinding Processes – from Laboratory to Production Scale

User seminar with the goal to impart the theoretical background and the function of agitator bead mills. The effect of important operating parameters on the grinding process will be discussed and various procedures will be explained.

Practical tests on the LabStar laboratory mill as well as on a production size machine will be used to demonstrate the effects discussed. Afterwards we will address the topics of particle size characterization and stabilization of suspensions (dispersion of ultrafine particles into the nanometer range).

 

Seminar Content:

  • Introduction to the NETZSCH Business Unit Grinding & Dispersing
  • Characterization of Successful Comminution – Terms and Definition
  • Overview of Grinding-media-free Dispersion Systems – Mixing, Wetting and Dispersion
  • Overview of NETZSCH Grinding Systems, Agitator Bead Mills
  • Effect of various Process Parameters
    • Model of the Stress Energy and the Stress Rate
    • Effect of the Dwell Time Distribution
    • Selection of the Grinding System and the mode of operation
  • Rheology
  • Grinding Media Selection and Scale-Up
    • Calculation – from Laboratory to Production Scale
  • Tour of Assembly area
  • Summary and Discussion
     

Optional (can be arranged after consultation):

  • Limits of Wet Grinding, True Comminution and Gentle Dispersion

PRACTICAL TRAINING | Implementation of laboratory tests – planning, performance, analysis, documentation 

After the user seminar, the theoretical knowledge acquired is now applied directly to our machines. In working groups with a maximum of 3 participants each, various tasks are carried out on different machines.

Here, the test materials undergo either true comminution or dispersion. During this workshop, advisors are available to provide support, but these are hands-on tasks for the participants.

 

Content:

  • Execution of a complete laboratory test, including setup and preparation of the test facility
    • Changing of the barrier fluid and measurement of the no-load curve
    • Filling of the machine with grinding media
    • Recording of a pump curve
  • Recording of important characteristics curves
  • Sampling and sample preparation for analysis of the test results
    • Processing of the sample material, including sampling and sample preparation
    • Characterization of the starting material
    • Troubleshooting basics
    • Handling Iris V3 system control
  • Documentation and discussion of the results

Course Information

Duration of the course: 3 days

Number of participants: max. 12

Course fee includes 

  • 3 nights lodging with breakfast
  • Catering during the event
  • Lunch / Dinner
  • Seminar documents

Seminar fee

  • Theory & Practice 1,900 € plus VAT

Register now!

  • Application Seminar
    26.01.2027 – 28.01.2027
    German
    NETZSCH-Feinmahltechnik GmbH/ Selb, Germany
  • Application Seminar
    16.03.2027 – 18.03.2027
    English
    NETZSCH-Feinmahltechnik GmbH/ Selb, Germany
  • Application Seminar
    09.11.2027 – 11.11.2027
    German
    NETZSCH-Feinmahltechnik GmbH/ Selb, Germany
  • Application Seminar
    30.11.2027 – 02.12.2027
    English
    NETZSCH-Feinmahltechnik GmbH/ Selb, Germany

General Information

Please use the appropriate registration form. The registrations will be handled in order of date of receipt.

Some days after registration, you will receive a confirmation. Shortly before the event, you will receive a description of how to reach the venue and - depending on the type of the event - a reservation confirmation for your hotel room.

For customers inside the EC: Please do always tell us your value added tax identification number.

Venue in Selb:Venue in Hanau:Venue in China
NETZSCH-Feinmahltechnik GmbH
Sedanstraße 70
95100 Selb
Germany
NETZSCH Trockenmahltechnik GmbH
Rodenbacher Chaussee 1
63457 Hanau
Germany
NETZSCH (Shanghai) 
Machinery and Instruments Co., 
Ltd. No.3136, Jia’an Road, Jiading, 
Shanghai 201814 P. R. China

In general, the accommodation costs are included in the course fee.

However, if they are not included, we request you to kindly pay for your hotel room when you check out.

For all the courses we offer, we have a certain number of rooms available at the location of the event or in close proximity. We would be happy to reserve a room for you at one of these hotels. For this purpose we require your date of arrival and departure.

Shortly before the courses and seminars or individual trainings have taken place you will receive a bill; which will be issued to the billing address we received from you. If you do not give us a billing address, the bill will be sent directly to the seminar participant. For seminars which take place in Germany, the legally valid VAT rate (currently 19 %) will be charged. (Exception: Customers from within the EU who have a VAT number)

The registration can be cancelled free-of-charge up to 14 days before the start of the event. If we receive cancellation at a later date, then any hotel costs incurred will be charged.

We require written cancellation. Surrogate participants are accepted.

If the program of the event is not available as a download on our website, then each participant will receive a complete event schedule by fax or e-mail shortly before the event.

We reserve the right to modify the schedule/program.

NETZSCH-Feinmahltechnik GmbH and NETZSCH Trockenmahltechnik GmbH reserve the right to cancel planned events up until one week before they begin. Should this be the case, affected participants will be informed immediately. NETZSCH-Feinmahltechnik GmbH and NETZSCH Trockenmahltechnik GmbH will not be liable for compensation for damages.

Any training documents and lists of participants from our events are only intended for the personal use of the participants. A duplication or disclosure of these documents to third persons is not allowed.

AI Overview
An error occurred. Please try again.