밝은 청록색에서 어두운 청록색으로 전환되는 그라데이션 배경은 미묘한 원형 라인이 특징이며 깔끔하고 현대적인 웹 디자인에 이상적입니다.

About us

NETZSCH Vakumix GmbH, Bremen / Germany

General Information

In February 2014 the Business Unit Grinding & Dispersing of the NETZSCH Group purchased the business of the company “VAKUMIX Rühr- und Homogenisiertechnik AG” and is going to resume the business activities as of March 1, 2014. With this step the Business Unit Grinding & Dispersing expands their product range in the field mixing, dispersing and homogenizing.

Under the new name “NETZSCH Vakumix GmbH” business will be continued from the current premises in Weyhe-Dreye near Bremen in Lower Saxony. The company “VAKUMIX Rühr- und Homogenisiertechnik AG” had been founded there back in 1995. The product range comprises customized systems like mixers, homogenizers, homogenizing mixers and process systems from the laboratory size up to a complete production plant. The machines are mainly used for pharmaceutical, cosmetic, chemical and food applications.

조경 공간과 자전거 주차장이 있는 매력적인 입구가 돋보이는 NETZSCH 바쿠믹스 GmbH의 현대적인 건물 외관.
제약, 화장품 및 식품 응용 분야를 위한 강력한 혼합 및 균질화 기술을 보여주는 NETZSCH 바쿠믹스 로고.

Profile

The road to success leads via NETZSCH Vakumix technology.

Because we at NETZSCH Vakumix are working on best solutions for your production and on best innovation for the quality and manufacture of your products.

Such that you are able to produce economically and to meet the constantly rising quality requirements of the market, our design engineers and process engineers developed a series of solutions which are of advantage to you in competition when you are producing your products.

  • robust machine design
  • high range of performance of the agitator and the homogenizer
  • short production times
  • high productivity with high quality of your products at the same time
  • effective and short CIP processes
  • automatic process management and its control
  • continuous and GAMP conform documentation
효율적인 균질화를 위한 네츠쉬의 첨단 혼합 기술을 강조하는 스테인리스 스틸 교반기의 물 속 클로즈업.

당사 직원들의 오랜 실무 경험도 귀사의 업무에 최적화된 기술을 찾는 데 도움이 됩니다.

브레멘에 위치한 본사를 통해 국내 및 해외 고객이 쉽게 접근할 수 있습니다.

이곳에서는 화장품, 제약, 화학 및 식품 산업의 많은 고객을 위해 NETZSCH 바쿠믹스 GmbH가 제조합니다.

품질, 성능, 생산성 및 기능에 있어 어떠한 타협도 하지 않는 NETZSCH Vakumix와 함께 다음 공장을 계획하면 그 혜택을 누릴 수 있습니다.

생산 효율성을 위한 첨단 공정 기술을 보여주는 NETZSCH 산업용 혼합 및 균질화 장비의 개략도입니다.

Divisions

You want more than just a vendor and our aim is more than just to supply a machine.

In a mutual partnership, we have far more possibilities to cope with the rising requirements of the market and thus to have influence on the success, the quality and on an economic production of your products.  

NETZSCH Vakumix offers its customers the investment security right from the start, as NETZSCH Vakumix always has the ideal solution for you, more than just a machine.

Talk to us! Thus we get to know your actual wishes and demands. Then, we will select different specialists from the individual divisions of the company to an effective project group and work out the best and most sensible solution for your company.

We provide our support to you in all necessary fields:

Research and Development
A laboraty equipped with different mixing and homogenizing plants is available for our customers. Here, you can test our performace and our quality as well as develop/test under GMP conditions or you can even produce small amounts.

Planning and Design
Together with our engineer team, you can plan your plant. Investment security right from the start has top priority at NETZSCH Vakumix. We take over your planning, even before large investments have been made and we show ideal ways and solutions for your requirements. Profit from the advantage “All from one source“, as we offer a comprehensive engineering with know-how of the whole production.

Manufacture
NETZSCH Vakumix is not “only“ able to plan, but also to manufacture. Because we know the possibilities which are feasible. Already in the planning phase, we recognize the difference between wish and feasibility and thus reduce costs right from the start.

After-Sales-Service
Even before manufacturing and supply, our specialists for the After-Sales-Service are integrated into the project. Their experiences reduce follow-up costs and secure you a production without problems.

Purchasing Department
Benefit from the experience of our purchasing department with world-wide contacts. We will be happy to support you with the search for suitable suppliers.

Sales
Naturally, the NETZSCH Vakumix Sales will assist you during the whole transaction. We will also be of assistance with all other problems. Please contact us and we will try to help you.

Plan your next plant with NETZSCH Vakumix, you will profit from it, as we do not make any compromises in quality, performance, productivity and functionality.

Quality Management

Your way to success leads via the quality and the performance of the NETZSCH Vakumix technology.

Because we at NETZSCH Vakumix always focus on the quality and the performance of our machines.

Our customers recommend NETZSCH Vakumix because...

  • NETZSCH Vakumix supplies powerful process technology for your task.
  • NETZSCH Vakumix supplies powerful homogenizing technology.
  • NETZSCH Vakumix supplies powerful mixing technology.
  • The products produced on NETZSCH Vakumix plants have a high quality.
  • NETZSCH Vakumix manufactures productive plants.
  • NETZSCH Vakumix plants have only little maintenance requirements.
  • NETZSCH Vakumix supplies high quality and advantageous technology.
GAMP 4 가이드라인은 제약 및 생명 과학 산업에서 제조 프로세스를 검증하고 품질을 보장하기 위한 모범 사례를 다룹니다.

Quality control and certifications by NETZSCH Vakumix:

NETZSCH Vakumix has the following authorizations:

  • Approval of the quality management system acc. to ISO 9001
     

Plan your next plant with NETZSCH Vakumix, you will profit from it, as we do not make any compromises in quality and functionality.

  • We meet the highest standards
  • Our plants meet the national and international regulations and standard design tests acc. to the European Explosion Proof Regulation ATEX
  • Pressure Vessel Approvals for our national and international customers

ATEX compliant plants

The new ATEX-Directive rules the resposibility and the design of the plant parts.

The operator of the plant is responsible for the allocation of the zone classification.

The lawmaker transferred the responsibility of the EEx-conformity to the owner of the plants by means of the new ATEX-Directive.

However, zone 0 means that all electrical and mechanical / dynamical installations used in the vessel have to be carried out according to ATEX Zone 0.

Zone 0 means that one “notified body“ (PTB, TÜV etc.) must test the use of all installed parts / fittings / agitators / pumps / sensors. These units have to be undergone to a EU-design test, that is that all electrical and mechanical / dynamical parts installed in the vessel must be carried out according to ATEX Zone 0.

Only such units / plants are allowed which have an EU-design test certificate or the evidence has to be provided that there are no ignition sources.

It is not sufficient that the gear motor, e. g. for an agitator, is supplied with an EU-design test certificate.

The evidence has to be brought that neither electric charging nor any ignition sources can come up at rotating parts / seals / agitator / scraper system and that defined flow velocities are kept. This has to be guaranteed with control units which have also to be proved with EU design test.
Thus the whole agitator subassembly has to be undergone an ATEX hazard analysis, such that an EU design test certificate can be issued.

NETZSCH Vakumix performs EU-design test as single test for the following components:

  • Agitator KappaVita
  • Homogenizers / Circulation Agitators LambdaVita
  • Control Equipment for LambdaVita

문의하기

NETZSCH 바쿠믹스 GmbH
Hermann-Köhl-Straße 3
28199 브레멘
독일
전화..: +49 421 8 49 56-0
이메일: info.nvm@netzsch.com

넷츠쉬 바쿠믹스는 지속 가능성 부문에서 에코바디스 실버 등급을 받아 평가 대상 기업 중 상위 15%에 속했습니다.
AI Overview
An error occurred. Please try again.