NETZSCH Pamir - Molino de Grano con Agitador Seco
Molienda en seco

Molino de bolas con agitador en seco Pamir

El molino de bolas con agitador para la molienda en seco más fina

Compared to the conventional Ball Mills, with the Pamir it is possible to obtain extremely fine products combined with very high throughput capacities at low specific energy consumption levels thanks to its operating mode and stress characteristics. Used together with NETZSCH classifiers in a grinding/classifying circuit, mineral fillers with a particle size of less than 2 µm can be produced.

It is continuously feed via a rotary airlock valve. A shaft equipped with exchangeable agitator tools is mounted inside the horizontally installed grinding vessel. The grinding media which are evenly distributed in the grinding vessel are kept in constant motion by the agitator tools and the resulting shearing /pressure - and impact stress ensures a very fine grinding result with a relatively low fineness fraction. The product discharges the mill either by gravity into a conveying system or will be transported by the classifying air to a separator.

This machine can be operated on its own in a single passage or alternatively with a NETZSCH Classifier. This combination puts the strengths of the Pamir to good use. The material coming from it, which is high in fineness and low in coarse followed by an inline classifier with high cutting precision, ensures the highest finenesses at low energy consumption.

The air classifier removes the fine product from the grinding circuit and the coarse product returns back to the mill together with the fresh feed. Thanks to the optimized operation mode, a low circulation load helps to obtain a specific and adjustable particle size distribution. NETZSCH can deliver the Bead Mill as an individual machine or as a complete turnkey plant.

Céntrate en tus puntos fuertes

Molienda energéticamente eficiente
Consigue una molienda ultrafina con un consumo energético considerablemente menor que el de los molinos de bolas convencionales.
Diseño compacto de la planta
Ahorra hasta un 75 % de espacio de instalación con un sistema compacto y fácil de integrar.
Calidad constante de los productos
Consigue distribuciones granulométricas estrechas con resultados reproducibles reliable.
Menor desgaste y molienda sin hierro
El recubrimiento de PU minimiza el desgaste y permite un rectificado sin hierro para aplicaciones delicadas.
Ampliación sin interrupciones
Amplía tu proceso de forma fiable, desde las pruebas piloto hasta la producción a gran escala.
Sustituto ideal para los molinos de bolas existentes
Sustituya los molinos de bolas convencionales por una solución de molienda compacta y eficiente desde el punto de vista energético.

Consulta sobre el producto

Le esperan soluciones personalizadas y asesoramiento experto Comience su proyecto hoy mismo

Su consulta

Tu contacto en NETZSCH

¿Tienes alguna pregunta? Ponte en contacto con nosotros.

También podría estar interesado en: 

AI Overview
An error occurred. Please try again.