About us
NETZSCH Vakumix GmbH, Weyhe-Dreye / Germany
General Information
In February 2014 the Business Unit Grinding & Dispersing of the NETZSCH Group purchased the business of the company “VAKUMIX Rühr- und Homogenisiertechnik AG” and is going to resume the business activities as of March 1, 2014. With this step the Business Unit Grinding & Dispersing expands their product range in the field mixing, dispersing and homogenizing.
Under the new name “NETZSCH Vakumix GmbH” business will be continued from the current premises in Weyhe-Dreye near Bremen in Lower Saxony. The company “VAKUMIX Rühr- und Homogenisiertechnik AG” had been founded there back in 1995. The product range comprises customized systems like mixers, homogenizers, homogenizing mixers and process systems from the laboratory size up to a complete production plant. The machines are mainly used for pharmaceutical, cosmetic, chemical and food applications.
„The product portfolio of the “VAKUMIX AG” and of the Business Unit Grinding & Dispersing ideally complement one another because there is no overlap of products. We will be able to offer our customers even better and more comprehensive solutions within the mixing and dispersion technology. At the same time we will strengthen our presence in the pharmaceutical and cosmetic sector,” said Dimitrios Makrakis, head of the Business Unit Grinding & Dispersing.
Profile
The road to success leads via NETZSCH Vakumix technology.
Because we at NETZSCH Vakumix are working on best solutions for your production and on best innovation for the quality and manufacture of your products.
Such that you are able to produce economically and to meet the constantly rising quality requirements of the market, our design engineers and process engineers developed a series of solutions which are of advantage to you in competition when you are producing your products.
- robust machine design
- high range of performance of the agitator and the homogenizer
- short production times
- high productivity with high quality of your products at the same time
- effective and short CIP processes
- automatic process management and its control
- continuous and GAMP conform documentation
The longtime experience of our employees in practice is also of assistance to you to find the optimum technology for your task.
The head office in Weyhe-Dreye, located directly at the outskirts of Bremen, enables our national and international customers an easy journey.
Here, NETZSCH Vakumix GmbH manufactures for many customers from the cosmetics, pharmaceutical, chemical and food industries.
Plan your next plant with NETZSCH Vakumix, you will benefit from it, as we do not make any compromises in quality, performance, productivity and functionality.
Divisions
You want more than just a vendor and our aim is more than just to supply a machine.
In a mutual partnership, we have far more possibilities to cope with the rising requirements of the market and thus to have influence on the success, the quality and on an economic production of your products.
NETZSCH Vakumix offers its customers the investment security right from the start, as NETZSCH Vakumix always has the ideal solution for you, more than just a machine.
Talk to us! Thus we get to know your actual wishes and demands. Then, we will select different specialists from the individual divisions of the company to an effective project group and work out the best and most sensible solution for your company.
We provide our support to you in all necessary fields:
Research and Development
A laboraty equipped with different mixing and homogenizing plants is available for our customers. Here, you can test our performace and our quality as well as develop/test under GMP conditions or you can even produce small amounts.
Planning and Design
Together with our engineer team, you can plan your plant. Investment security right from the start has top priority at NETZSCH Vakumix. We take over your planning, even before large investments have been made and we show ideal ways and solutions for your requirements. Profit from the advantage “All from one source“, as we offer a comprehensive engineering with know-how of the whole production.
Manufacture
NETZSCH Vakumix is not “only“ able to plan, but also to manufacture. Because we know the possibilities which are feasible. Already in the planning phase, we recognize the difference between wish and feasibility and thus reduce costs right from the start.
After-Sales-Service
Even before manufacturing and supply, our specialists for the After-Sales-Service are integrated into the project. Their experiences reduce follow-up costs and secure you a production without problems.
Purchasing Department
Benefit from the experience of our purchasing department with world-wide contacts. We will be happy to support you with the search for suitable suppliers.
Sales
Naturally, the NETZSCH Vakumix Sales will assist you during the whole transaction. We will also be of assistance with all other problems. Please contact us and we will try to help you.
Plan your next plant with NETZSCH Vakumix, you will profit from it, as we do not make any compromises in quality, performance, productivity and functionality.
Quality Management
Your way to success leads via the quality and the performance of the NETZSCH Vakumix technology.
Because we at NETZSCH Vakumix always focus on the quality and the performance of our machines.
Our customers recommend NETZSCH Vakumix because...
- NETZSCH Vakumix supplies powerful process technology for your task.
- NETZSCH Vakumix supplies powerful homogenizing technology.
- NETZSCH Vakumix supplies powerful mixing technology.
- The products produced on NETZSCH Vakumix plants have a high quality.
- NETZSCH Vakumix manufactures productive plants.
- NETZSCH Vakumix plants have only little maintenance requirements.
- NETZSCH Vakumix supplies high quality and advantageous technology.
Quality control and certifications by NETZSCH Vakumix:
NETZSCH Vakumix has the following authorizations:
- Approval of the quality management system acc. to ATEX TÜV 04 ATEX 2681 Q
- Agitator KappaVita Type HM/VHM: TÜV 06 ATEX 2760 X
- Homogenizer LambdaVita Type DHO: TÜV 04 ATEX 2637
- Circulation Agitator Type UMR: TÜV 04 ATEX 2608 X
- Control Equipment: TÜV 04 ATEX 2680
Plan your next plant with NETZSCH Vakumix, you will profit from it, as we do not make any compromises in quality and functionality.
- We meet the highest standards
- Our plants meet the national and international regulations and standard design tests acc. to the European Explosion Proof Regulation ATEX
- Pressure Vessel Approvals for our national and international customers
ATEX compliant plants
The new ATEX-Directive rules the resposibility and the design of the plant parts.
The operator of the plant is responsible for the allocation of the zone classification.
The lawmaker transferred the responsibility of the EEx-conformity to the owner of the plants by means of the new ATEX-Directive.
However, zone 0 means that all electrical and mechanical / dynamical installations used in the vessel have to be carried out according to ATEX Zone 0.
Zone 0 means that one “appointed authority“ (PTB, TÜV etc.) must test the use of all installed parts / fittings / agitators / pumps / sensors. These units have to be undergone to a EC-design test, that is that all electrical and mechanical / dynamical parts installed in the vessel must be carried out according to ATEX Zone 0.
Only such units / plants are allowed which have an EC-design test certificate or the evidence has to be provided that there are no ignition sources.
It is not sufficient that the gear motor, e. g. for an agitator, is supplied with an EC-design test certificate.
The evidence has to be brought that neither electric charging nor any ignition sources can come up at rotating parts / seals / agitator / scraper system and that defined flow velocities are kept. This has to be guaranteed with control units which have also to be proved with EC design test.
Thus the whole agitator subassembly has to be undergone an ATEX hazard analysis, such that an EC design test certificate can be issued.
In order to make sure that the ATEX regulation can be adhered and that the machine is supplied with an EC compliant certificate, a specially authorized ATEX person is necessary at the supplier. This person is responsible for making sure that the designs have an ATEX compliant version and that a safety analysis is carried out, in order to start necessary measures and tests at the machine.
The name of the ATEX – authorized person has to be deposited at the registration office. This person is responsible for an ATEX compliant supply.
The qualifications and workflows of the manufacturer are tested and certified on the basis of a quality management system by the TÜV or PTB authorized person.
The supplied machines with the corresponding ATEX compliant approval have to be listed up in a list which is checked by the registration office. If the company does not fulfill these requirements, the company loses its ATEX approval.
NETZSCH Vakumix has the following certifications:
- Approval of the quality management system accoording to ATEX TÜV 04 ATEX 2681 Q
- Agitator KappaVita Type HM/VHM: TÜV 06 ATEX 2760 X
- Homogenizer LambdaVita Type DHO: TÜV 04 ATEX 2637
- Circulation Agitator Type UMR: TÜV 04 ATEX 2608 X
- Control Equipment: TÜV 04 ATEX 2680
If foreign parts are installed, the supplier of these foreign parts has to meet the same requirements and has to prove design tests and to provide the corresponding documentation.
Contact us
NETZSCH Vakumix GmbH
Zeppelinstraße 1
D-28844 Weyhe - Dreye
Germany
Tel.: +49 421 8 49 56-0
Fax: +49 421 8 49 56-90
e-mail: info.nvm@netzsch.com